Function: | Flow Control |
---|---|
Installation: | Threaded Cartridge |
Drive: | Hydraulic |
Type: | Directly Operated Type |
Transport Package: | Box |
Specification: | Hydraulic proportional directional control valv |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Hydraulic valve design principle
The design of the hydraulic valve is mainly for the design of the hydraulic valve group, and the oil circuit must be considered before the design of the hydraulic valve group. It is necessary to determine in advance which parts of the oil circuit can be integrated. The design of the oil circuit must be simple and save Go unnecessary steps. After determining the oil circuit, the main thing is the oblique hole and the process hole. These things in the oil path should be reduced. As long as it is enough, it is not necessary too much. Pay attention to the hole diameter in the design of the oblique hole and the process hole.
Collecting valve
|
|
Maintaining valve
|
Throttle valve
|
Relief valve
|
Solenoid directional valve
|
Speed regulation valve
|
Pressure reducing valve
|
Manual reversing valve
|
Diverter valve
|
Pressure valve
|
Check valve
|
Flow valve
|
Cartridge valve
|
Hydraulic control one-way valve
|
Collecting valve
|
Stop valve
|
Solenoid valve
|
Pilot valve
|
Reverse check valve
|
Superposition valve
|
Direct acting relief valve
|
Pilot check valve
|
Directional valve
|
Pilot relief valve
|
Sequence valve
|
Pilot sequence valve
|
Pilot reducing valve
|
Balance valve
|
Direct acting sequence valve
|
We have strict quality control system for 4wree valve,hydraulic valve 4WRKE :
1. External Inspection: Purchased Item Inspection, Outsourcing Item Inspection
2. Process Inspection: First Inspection, Random Inspection, Handover Inspection
3. Final Quality Inspection: External Dimensions Inspection, 100% Hydraulic Test
Important Voltage supply 24 V DC nom, if voltage drops below 18 V DC, rapid shutdown resembling "Enable OFF" takes place internally. In addition, with the "mA signal" version: ID-E 3 mA - valve is active ID-E 2 mA - valve is deactivated. Electrical signals emitted via the trigger electronics (e.g. actual values) must not be used to shut down safetyrelevant machine functions! (Also see European Standard, "Technical Safety Requirements for Fluid-Powered Systems and Components - Hydraulics", EN 982
Solenoid valve with flow control,valve dbw, 4wree valve, hydraulic valve 4WRKE. This series are used to control the start, stop and direction of flow.
4WH series hydraulic operated directional valves can be used to change the direction
of hydraulic oil by moving the main spool when the valve receives a hydraulic signal
from the pilot hydraulic oil.
Model include: 4WRA10E30-2X/G24K4/V 4WRA10E30-2X/G24N9K4/V 4WRA10E60-2X/G24K4/V 4WRA10E60-2X/G24N9K4/V 4WRA10EA30-2X/G24K4/V 4WRA10EA30-2X/G24N9K4/V 4WRA10EA60-2X/G24K4/V 4WRA10EA60-2X/G24N9K4/V 4WRA10E1-30-2X/G24K4/V 4WRA10E1-30-2X/G24N9K4/V 4WRA10E1-60-2X/G24K4/V 4WRA10E1-60-2X/G24N9K4/V 4WRA10W30-2X/G24K4/V 4WRA10W30-2X/G24N9K4/V 4WRA10W60-2X/G24K4/V 4WRA10W60-2X/G24N9K4/V 4WRA10WA30-2X/G24K4/V 4WRA10WA30-2X/G24N9K4/V 4WRA10WA60-2X/G24K4/V 4WRA10WA60-2X/G24N9K4/V 4WRA10W1-30-2X/G24K4/V 4WRA10W1-30-2X/G24N9K4/V 4WRA10W1-60-2X/G24K4/V 4WRA10W1-60-2X/G24N9K4/V 4WRAE6E07-2X/G24K31/A1V
4WRA10E30-2X/G24K4/V,4WRA10E60-2X/G24K4/V,4WRA10E1-30-2X/G24K4/V
4WRA10E1-60-2X/G24K4/V,4WRA10EA30-2X/G24K4/V,4WRA10EA60-2X/G24K4/V
4WRA10W30-2X/G24K4/V,4WRA10W60-2X/G24K4/V,4WRA10W1-30-2X/G24K4/V
4WRA10W1-60-2X/G24K4/V,4WRA10WA30-2X/G24K4/V
Suppliers with verified business licenses